HRD33 30-40kVA Rack Online UPS - INVT Electric Global

HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)

HRD Series UPS is a fully digital, double conversion online UPS with three-phase input and three-phase output, providing high-reliability, clean and stable power supply. Featuring high power density and standard cabinet dimensions, it is ideal for various deployments ranging from IT racks, network cabinets, automatic control systems and precision instruments to small control rooms and other edge applications.

·Tower/Rack convertible UPS
·10~40kVA
·Three Phase in, Three Phase out
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
VideoVideo
ImagesImages
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
    HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
  • HRD33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Strict tests including dust, safety, high and low temperature limit, vibration and EMC

01

Independent air duct design for better protection of sensitive components

02

High-reliability bypass with stronger load impact resistance and larger thermal margin

03

3U height, depth 520/680mm, suitable for server cabinets with depth ≥1000mm

04

High efficiency: up to 96.5% in double conversion mode, up to 99% in ECO mode

05

Input THDi < 3%, output THDv < 5% (100% non-linear load)

06

Specifications

System Capacity

30kVA/30kW

40kVA/40kW

Input

Dual Input

Standard

Phase

3 Phase+Neutral+Ground, 380V/400V/415V (line-line)

Input Voltage Range

304~478Vac (line-line), full load; 228~304Vac (line-line), derate from 75% to 100% load

Rate Frequency

50/60Hz

Input Frequency Range

40Hz~70Hz

Input PF

≥0.99

Input THDi

<4% (100% Linear load)

Bypass

Rate Voltage

380/400/415VAC (line-line)

Rate Frequency

50/60Hz

Input Voltage Range

Settable, -40%~+25%

Bypass Frequency Range

Settable, ±1Hz, ±3Hz, ±5Hz

Bypass Overload

125% long term operation; 130% for 10 mins; 150% for 1 min, >150% for 1s

Output

Rate Voltage

380/400/415VAC (line-line)

Voltage Regulation

1% for balance load; 1.5% for unbalance load

Rate Frequency

50/60Hz

Output PF

1

Output THDu

<1%, Linear load;

<5.5%, Non-linear load

Crest Factor

3:01

Inverter Overload

110% for 1 hour then transfer to bypass; 125% for 10 mins then transfer to bypass; 150% for 1 min then transfer to bypass; >150% for 200 ms then transfer to bypass

Frequency Precision

0.10%

Battery

Voltage

Default 192VDC (192VDC~288VDC configurable)

Battery Number

40pcs (Settable: even number from 32 to 44)

Voltage Precision

±1%

Charge Power

up to 20% * Output active power

Battery Cold Start

Standard

System

Efficiency

Main Mode

>96.5%

ECO Mode

99%

Display

LCD + LED + keyboard

IP Class

IP 20

Interface

RS232, EPO

Option

DB9 dry contact card, parallel card, Type B USB, SNMP card, RS485, 12A charger

Temperature

Operation: 0~40 ℃ Storage: -40~70 ℃

Relative Humidity

0~95% Non-condensing

Altitude

<1000m. Within 1000m~2000m, 1% power derating for every 100m

Noise(1 meter)

<62dB

Applicable Standards

Safety: IEC/EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3

Physical

Weight(kg)

28

DimensionW*D*H(mm)

438*762*130(3U)