GD350-13 Series VFD for Pump Jacks

The GD350-13 series Variable Frequency Drive (VFD) supports both synchronous and asynchronous motors. It is suitable for various pumping units, including tower pumping units, beam pumping units (power jacks), and direct-drive progressive cavity pumps. It features enhanced reliability and environmental adaptability alongside customized and industry-specific designs, delivering optimized functions, superior control performance, and flexible application.

·11~75kW
·380~690V
·Certified to CE, EAC, and other standards
  • GD350-13 Series VFD for Pump Jacks
ImagesImages
  • GD350-13 Series VFD for Pump Jacks
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Compatibility with various types of pumping units
Integrates dedicated control functions for different types of pumping units, including tower pumping units, beam pumping units (power jacks), and direct-drive progressive cavity pumps.
01
Energy saving and efficiency improvement
Real-time reduction of reactive power according to load changes, saving more than 20% of energy compared to the previous generation. Independent upward and downward speed settings enable more pumping cycles within the same time. Automatic operational adjustments via monitoring data ensure precise equipment control and enhanced production efficiency.
01
Reduced maintenance costs
Supports mine monitoring functions, adding features such as oil balance rate detection and dynamic liquid level detection. It provides real-time monitoring of the well status, enabling early identification of potential equipment issues to facilitate proactive maintenance scheduling. This prevents production downtime while simultaneously reducing repair costs.
03
Automated extraction and equipment safety assurance
The system supports sleep/wake-up mode activation via external signals or timer settings, enabling low-power swinging actions at the optimal balance position, reducing the risk of safety incidents caused by abnormal equipment startup.
04

Specifications

Item

Specifications

Power input

Input voltage (V)

AC 3PH 380V (-15%)–440V(+10%); rated voltage: 380V

AC 3PH 520V (-15%)–690V (+10%); rated voltage: 660V

Input frequency (Hz)

50Hz or 60Hz; allowed range: 47–63Hz

Power output

Output voltage (V)

0–input voltage

Output frequency (Hz)

0–400Hz

Technical control performance

Control mode

Space voltage vector control, sensorless vector control (SVC), and feedback vector control (FVC) mode

Motor type

Asynchronous motor (AM) and permanent magnet synchronous motor (SM)

Speed ratio

AM: 1:200 (SVC)
SM: 1:20 (SVC), 1:1000 (FVC)

Speed control accuracy

±0.2% (SVC), ±0.02% (FVC)

Speed fluctuation

±0.3% (SVC)

Torque response

<20ms (SVC), <10ms (FVC)

Torque control accuracy

10% (SVC), 5% (FVC)

Starting torque

AM: 0.25Hz/150% (SVC)

SM: 2.5Hz/150% (SVC)

0Hz/200% (FVC)

Overload capacity

Able to run at 150% of the rated current for 1 minute, 180% of the rated current for 10 seconds, and 200% of the rated current for 1 second.

Running control performance

Frequency setting method

Settings can be implemented through digital, analog, pulse frequency, multi-step speed running, simple PLC, PID, Modbus communication, PROFIBUS communication and so on.

Settings can be combined and the setting channels can be switched.

Automatic voltage regulation (AVR)

The output voltage can be kept constant although the grid voltage changes.

Fault protection

More than 30 protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload.

Start after speed tracking

Enables smooth startup of a rotating motor.

Note: Applicable to models ≥ 4kW

Transient power loss ride-through

In the event of a transient power drop, the VFD continues to operate using the regenerated energy, ensuring no downtime.

Dual motor switching

Supports switching between two sets of motor parameters.

Peripheral interface

Terminal analog input resolution

No more than 20mV

Terminal digital input resolution

No more than 2ms

Analog input

Two inputs; AI1: 0–10V/0–20mA; AI2: -10–+10V

Analog output

One output; AO1: 0–10V/0–20mA

Digital input

Four regular inputs; max. frequency: 1kHz; internal impedance: 3.3kΩ

Two high-speed inputs; max. frequency: 50kHz; supporting quadrature encoder input; with speed measurement function

Digital output

One high-speed pulse output; max. frequency: 50kHz

One Y terminal open collector output

Relay output

Two programmable relay outputs

RO1A: NO; RO1B: NC; RO1C: common

RO2A: NO; RO2B: NC; RO2C: common

Contact capacity: 3A/AC250V, 1A/DC30V

Expansion interfaces

Three expansion interfaces: SLOT1, SLOT2, and SLOT3 (available on control boards for VFDs 7.5kW and above).

Support PG cards, programmable expansion cards, communication cards, I/O cards, and other cards.

Other

Mounting method

Supports wall mounting, floor mounting, and flange mounting.

Temperature of running environment

-10°C–+50°C. Derating is required when the ambient temperature exceeds 40°C.

Ingress protection (IP) rating

IP20

Pollution degree

Degree 2

Cooling method

Forced air cooling

Braking unit

380V 11kW–75kW (inclusive) models: Standard (built-in)

660V models: Optional (external)

EMC filter

All 380V models can meet IEC/EN 61800-3 C3 requirements for conducted emissions.

Optional external filters can be used to meet the IEC61800-3 C2 requirements for conducted emissions.

Note: Comply with the EMC specifications required in the manual appendix. Motors and motor cables shall be selected according to the technical requirements specified in the manual appendix.