GD350-21 Series Dual-VFD Integrated System for Air Compressor

The GD350-21 series dual-VFD integrated system for air compressor is developed on the foundation of the existing GD300-21 series Variable Frequency Drive (VFD). It incorporates a new-generation control platform technology and is specifically designed around the characteristics of air compressors. As a high-end, fully integrated solution for air compressors that provides full variable frequency control for both the motor and fan, it perfectly achieves integrated drive and management for air compression systems.

·15~90kW
·380V
·IP rating: IP20
  • GD350-21 Series Dual-VFD Integrated System for Air Compressor
  • GD350-21 Series Dual-VFD Integrated System for Air Compressor
ImagesImages
  • GD350-21 Series Dual-VFD Integrated System for Air Compressor
  • GD350-21 Series Dual-VFD Integrated System for Air Compressor
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Intelligent control algorithms for stable and reliable operation
Features a low-harmonic control algorithm to reduce motor temperature rise and extend motor service life.
Multiple control modes (V/F, vector, and VVC) for different motor load types.
Control loop bandwidth increased by 10×, with enhanced grid/load fluctuation adaptability for more stable operation.
01
Dedicated design for simplicity and ease of use
Standard LED keypad with intuitive display and parameter copy function for convenient commissioning of motor and fan parameters.
Compatible with motor parameters from multiple brands, reducing parameter-matching faults such as OC, STO, and DEU, and ensuring long-term stable operation of the air compressor.
Built-in logic and interfaces designed for air compressors, eliminating the need for a dedicated controller or PLC. It supports dual-VFD control for both the motor and the oil-cooling fan, enabling greater energy savings through constant temperature control.
Built-in 110V/220V power-frequency transformer and dedicated solenoid valve relay interface for direct valve control.
Cooling fans with IP56 vacuum-coated design, significantly reducing fan failure rate and improving system reliability.
Built-in DC reactor as standard across the entire series.
02

Specifications

Category

Item

Specifications

Power input

VFD input voltage (V)

3PH AC 220V (-15%)–240V (+10%)

3PH AC 380V (-15%)–440V (+10%)

Rated input frequency (Hz)

50Hz or 60Hz; allowed range: 47–63Hz

VFD core module efficiency

>97%

Main motor VFD power output

Output voltage (V)

Equal to the input voltage, with the error <5%

Output frequency (Hz)

0–400Hz

Fan VFD power output

Output voltage (V)

Equal to the input voltage, with the error <5%

Output frequency (Hz)

0–50Hz

Other power output

+24VDC power supply

Rated load power: 24W

220VAC/110VAC

Rated load power: 30W

Running control performance

Control mode

Open-loop vector, space voltage vector

Speed ratio

Asynchronous motors (AMs): 1:200 (SVC)
synchronous motors (SMs): 1:20 (SVC)

Speed control accuracy

±0.2% (SVC)

Speed fluctuation

±0.3% (SVC)

Torque response

<20ms (SVC)

Starting torque

For AMs: 0.25Hz  150% (SVC)

For SMs: 2.5Hz  150% (SVC)

Overload capacity

Main motor VFD: 150% for 1 minute

Fan VFD: 112% for 1 minute

Dedicated functions

Sleep and wake-up, constant pressure control, constant temperature control, part maintenance, phase sequence detection, and fan overload protection

Analog input of pressure

Two 0–20mA/0–10V inputs

Analog input of temperature

Two temperature analog inputs; resolution: 1°C; range: -40℃–+200°C

Digital input

Five regular digital inputs; max. frequency: 1kHz

Digital output

One regular digital output; 50mA/30V

Solenoid valve

One set of solenoid valve coil control voltage output terminals T1A/T1C, providing AC 220V or 110V, with a maximum load capacity of 30W

Relay output

One set of normally open dry contact terminals RO2A/RO2C, contact rating 3A/AC250V or 1A/DC30V

Safe torque off (STO) input

Two inputs, STO1 and STO2

Fault protection

More than 30 protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload.

RS485 communication

One RS485 communication

Solenoid valve output

Default 220V, configurable for 110V coil output, maximum power 30W

Other

Mounting method

Wall mounting or floor mounting

Temperature of running environment

-10°C–+50°C
Derating is required when the ambient temperature exceeds 40°C. Derate by 1% for each increase of 1°C.

Ingress protection (IP) rating

IP20

Cooling method

Forced air cooling

DC reactor

Standard configuration

EMC filter

Optional external filters can be used to meet the IEC61800-3 C2 requirements.