| Item | Specification | ||
| Power input | Input voltage (V) | AC 3PH 200V–240V; rated voltage: 220V AC 3PH 380V–480V; rated voltage: 460V AC 3PH 520V–600V; rated voltage: 575V | |
| Allowed voltage transient fluctuation | -15% – +10% | ||
| Input frequency (Hz) | 50Hz or 60Hz; allowed range: 47–63Hz | ||
| Power output | Output voltage (V) | 0–input voltage | |
| Output frequency (Hz) | 0–400Hz | ||
| Technical control performance | Control mode | Space voltage vector control, sensorless vector control (SVC), and feedback vector control (FVC) mode | |
| Motor type | Asynchronous motor (AM) and permanent magnet synchronous motor (SM) | ||
| Speed ratio | For AM, 1:200 (SVC); for SM, 1:20 (SVC), 1:1000 (FVC) | ||
| Speed control accuracy | ±0.2% (SVC); ±0.02% (FVC) | ||
| Speed fluctuation | ±0.3% (SVC) | ||
| Torque response | <20Ms (SVC); <10ms (FVC) | ||
| Torque control accuracy | 10% (SVC); 5% (FVC) | ||
| Starting torque | For AMs: 0.25Hz/150% (SVC) For SMs: 2.5Hz/150% (SVC) 0Hz/200% (FVC) | ||
| Overload capacity | G type: Able to run at 150% of the rated current for 1 minute, 180% of the rated current for 10 seconds, and 200% of the rated current for 1 second. P type: Able to run at 120% of the rated current for 1 minute, 150% of the rated current for 10 seconds, and 180% of the rated current for 1 second. | ||
| Running control performance | Frequency setting method | Settings can be implemented through digital, analog, pulse frequency, multi-step speed running, simple PLC, PID, Modbus/Modbus TCP communication, PROFIBUS communication and so on. Settings can be combined and the setting channels can be switched. | |
| Automatic voltage regulation (AVR) | The output voltage can be kept constant although the grid voltage changes. | ||
| Fault protection | More than 30 protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload. | ||
| Start after speed tracking | Enables smooth startup of a rotating motor. Note: Applicable to models ≥ 4kW | ||
| Transient power loss ride-through | Maintains operation through regenerated energy during a transient power loss. | ||
| Dual motor switching | Supports switching between two sets of motor parameters. | ||
| STO | SIL2 | ||
| Peripheral interface | Terminal analog input resolution | No more than 20mV | |
| Terminal digital input resolution | No more than 2ms | ||
| Analog input | Two inputs; AI1: 0–10V/0–20mA; AI2: -10–+10V | ||
| Analog output | One output; AO1: 0–10V/0–20mA | ||
| Digital input | Four regular inputs; max. frequency: 1kHz; internal impedance: 3.3kΩ Two high-speed inputs; max. frequency: 50kHz; supporting quadrature encoder input; with speed measurement function | ||
| Digital output | One high-speed pulse output; max. frequency: 50kHz One Y terminal open collector output | ||
| Relay output | Two programmable relay outputs RO1A: NO; RO1B: NC; RO1C: common RO2A: NO; RO2B: NC; RO2C: common Contact capacity: 3A/AC250V, 1A/DC30V | ||
| Expansion interfaces | Three expansion interfaces: SLOT1, SLOT2, and SLOT3 (220V 0.75kW and 460V 1.5–2.2kW models feature only two expansion interfaces.) Supports PG cards, programmable expansion cards, communication cards, I/O cards, and other cards. | ||
| Other | Mounting method | Supports wall mounting, floor mounting, and flange mounting. | |
| Temperature of running environment | -10°C–+50°C. Derating is required when the ambient temperature exceeds 40°C. For details, refer to the derating section in the manual. | ||
| Ingress protection (IP) rating | IP20 | ||
| Pollution degree | Degree 2 | ||
| Cooling method | Fan cooling | ||
| Braking unit | Standard built-in: Models 220V ≤15kW; 460V ≤30kW; 575V ≤18.5kW Optional: Models 220V 18.5–55kW; 460V ≥37kW; 575V ≥22kW | ||
| EMC filter | All 220V and 460V models: Standard built-in C3 filter Meets IEC 61800-3 C3 requirements with a motor cable length up to 10m. | ||
| Overvoltage category | 200–240V input: A transient surge suppressor (suitable for Overvoltage Category III) shall be installed on the VFD mains side, rated at 220V (phase-to-ground) and 220V (phase-to-phase), providing protection at a rated impulse withstand voltage peak of 4kV. 380–480V input: A transient surge suppressor (suitable for Overvoltage Category III) shall be installed on the VFD mains side, rated at 480V (phase-to-ground) and 480V (phase-to-phase), providing protection at a rated impulse withstand voltage peak of 6kV. 520–600V input: A transient surge suppressor (suitable for Overvoltage Category III) shall be installed on the VFD mains side, rated at 575V (phase-to-ground) and 575V (phase-to-phase), providing protection at a rated impulse withstand voltage peak of 6kV. | ||
GD350-UL Series High-Performance Multifunction VFD
The GD350-UL series is a high-performance multifunction Variable Frequency Drive (VFD). It can drive both synchronous and asynchronous motors, supporting torque, speed, and position control. Designed for industrial applications, it offers enhanced reliability, usability, maintainability, and environmental adaptability, together with rich functions and flexible configuration. The VFD models in some power ranges carry built-in braking units to save installation space. Through overall EMC design, the VFD can satisfy the low noise and low electromagnetic interference requirements to cope with challenging grid, temperature, humidity and dust conditions, thus greatly improving product reliability.
Features




Specifications
Downloads
More Resources
Have questions or need support?
Our professional team is here to help.



Repair Progress Tracking | Identity Verification
To protect your repair information, please verify using the mobile number reserved on the service order.

Contact INVT
Get in touch with INVT. Our team will get back to you shortly.
-
Industrial Automation
-
Network Power
-
PV & ESS
-
e-Mobility