GD200A Series General-Purpose VFD

The GD200A is a highly reliable general-purpose Variable Frequency Drive (VFD) covering a power range of 0.75kW to 3000kW. Since its launch, more than one million units have been deployed across diverse applications, with extensive use in municipal, metalworking, chemical, steel, papermaking, petroleum, HVAC, and food industries.

·0.75-500kW
·Supports G/P type load
·CE, UKCA, and EAC certified
  • GD200A Series General-Purpose VFD
VideoVideo
ImagesImages
  • GD200A Series General-Purpose VFD
    GD200A Series General-Purpose VFD
  • GD200A Series General-Purpose VFD
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Versatile and easy to use
Supports wall mounting, flange mounting, and floor mounting.
Supports shared DC bus and DC power supply mode.
Integrated with customized functions such as dedicated water supply mode, simple PLC programming, and speed tracking.
01
Stable and reliable
Independent air duct design with enhanced conformal coating for circuit boards, improving adaptability to harsh environments.
Standard built-in C3 filter; optional external C2 filter to minimize EMI.
02
Certified to multiple standards
CE, UKCA, and EAC certified.
Complies with IEC/EN 61800-9-2 energy efficiency standards.
03

Specifications

ItemSpecifications
Power input Input voltage (V) AC 3PH 380V (-15%)–440V (+10%)
Input frequency (Hz) 50Hz or 60Hz; allowed range: 47–63Hz
Power output Output voltage (V) 0–input voltage
Output frequency (Hz) 0–400Hz
Technical control performance Control mode Sensorless vector control (SVC), and space voltage vector control
Motor type Asynchronous motor (AM)
Speed ratio For asynchronous motor (AM): 1:100 (SVC)
Speed control accuracy ±0.2% (SVC)
Speed fluctuation ±0.3% (SVC)
Torque response <20ms (SVC)
Torque control accuracy 10% (SVC)
Starting torque For AMs: 0.5Hz/150% (SVC)
Overload capacity Able to run at 150% of the rated current for 1 minute, 180% of the rated current for 10 seconds, and 200% of the rated current for 1 second (G type).
Running control performance Frequency setting method Settings can be implemented through digital, analog, pulse frequency, multi-step speed run, simple PLC, PID, and MODBUS communication. Settings can be combined and the setting channels can be switched.
Automatic voltage regulation (AVR) The output voltage can be kept constant although the grid voltage changes.
Fault protection More than 30 protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload.
Start after speed tracking Enables smooth startup of a rotating motor.
Peripheral interface Terminal analog input resolution No more than 20mV
Terminal digital input resolution No more than 2ms
Analog input One input (AI2) 0–10V/0–20mA; one input (AI3) -10–+10V
Analog output Two inputs (AO1, AO2) 0–10V/0–20mA
Digital input Eight regular inputs; max. frequency: 1kHz One high-speed input; max. frequency: 50kHz
Digital output One high-speed pulse output; max. frequency: 50kHz. One Y terminal open collector output.
Relay output Two programmable relay outputs RO1A: NO; RO1B: NC; RO1C: common RO2A: NO; RO2B: NC; RO2C: common Contact capacity: 3A/AC250V, 1A/DC30V
Other Mounting method Supports wall mounting, floor mounting, and flange mounting.
Temperature of running environment -10°C–+50°C. Derating is required when the ambient temperature exceeds 40°C.
Ingress protection (IP) rating IP20
Cooling method Forced air cooling
Braking unit Models ≤ 30kW: Built-in Other models: Optional external
EMC filter All the series meet the IEC61800-3 C3 requirements. Optional external filters can be used to meet the IEC61800-3 C2 requirements. 

Downloads

Have questions or need support?

Our professional team is here to help.

Inquiry
TOP
We use cookies to understand how our audience uses our site.
Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie policy.
Accept
Reject
Cancel