Item | Specifications | |
Input | Input voltage | AC 3PH 380~480V Rated voltage:380V |
| Input frequency | 50Hz or 60Hz; Allowed range: 47–63Hz | |
| Allow voltage transient fluctuations | -15%~+10% | |
Output | Output voltage (V) | 0–Input voltage (V) |
| Output frequency (Hz) | 0–400Hz | |
Control performance | Control mode | Sensorless vector control (SVC) mode, and field vector control (FVC) mode |
| Motor type | Asynchronous motor (AM) and permanent magnet synchronous motor (SM) | |
| Speed ratio | For AMs: 1:200 (SVC) For SMs: 1:20 (SVC) | |
| Speed control accuracy | ±0.2% (SVC) | |
| Speed fluctuation | ±0.3% (SVC) | |
| Torque response | <20ms (SVC) | |
| Torque control accuracy | ±10% (SVC) | |
| Overload capacity | 110% of the rated current for 60s, overloading allowed once every 5 minutes | |
Operation performance | Frequency setting | Digital settings, analog settings, pulse frequency settings, multi-step speed settings, simple PLC settings, PID settings, communication settings, etc. It can achieve combinations of settings and switching between setting channels. |
| Automatic voltage regulation | Maintains constant output voltage automatically when grid voltage fluctuates | |
| Fault protection | Provides multiple fault protection functions: overcurrent, overvoltage, undervoltage, overtemperature, phase loss, overload, and other protection functions | |
| Speed Tracking Restart Function | Achieve smooth, impact-free startup for a rotating motor | |
Peripheral interface | Terminal analog input resolution | No more than 20mV |
| Terminal digital input resolution | No more than 2ms | |
| Analog input | 2 inputs. AI1: 0(2)–10V/0(4)–20mA, AI2: -10~10V | |
| Analog output | 2 inputs. AO0/AO1:0(2)~10V/0(4)~20mA | |
| Digital input | 5 regular inputs. Max. frequency: 1kHz; internal impedance 3.3kΩ 1 high-speed input. Max. frequency: 50kHz | |
| Digital output | 1 Y terminal open collector output | |
| Relay output | 2 programmable relay outputs. RO1A: NO; RO1B: NC; RO1C: common; RO2A: NO; RO2B: NC: RO2C: common Contact capacity: 3A/AC250V, 1A/DC30V | |
| Expansion terminal | 2 expansion terminals: SLOT1, SLOT2. Expandable communication cards, I/O cards, etc. | |
Environment requirements and certification | Mounting method | Wall mounting, floor mounting, flange mounting |
| Cooling method | Forced air cooling | |
| Temperature of running environment | -10°C – +50°C. Derating is required when the ambient temperature exceeds 40°C. | |
| Ingress protection (IP) rating | IP20 | |
| Pollution degree | PD2 | |
GD290L Series Escalator-Dedicated VFD
GD290L escalator-dedicated VFD is specially designed for escalator and moving walkway applications. It adopts advanced vector control technology to ensure stable operation under complex load conditions, with high reliability, strong EMC performance, and optimized energy efficiency during light-load and low-speed operation. With flexible communication expansion and compact structure, it is widely used in shopping malls, subways, airports, and other public transportation facilities, helping customers reduce system cost and energy consumption.
Features





Specifications
More Resources
Have questions or need support?
Our professional team is here to help.



Repair Progress Tracking | Identity Verification
To protect your repair information, please verify using the mobile number reserved on the service order.

Contact INVT
Get in touch with INVT. Our team will get back to you shortly.
-
Industrial Automation
-
Network Power
-
PV & ESS
-
e-Mobility