GD20-09 Series VFD for Hoisting

GD20-09 Series VFD for Hoisting

The GD20-09 series of crane-specific inverters are specially designed open-loop vector inverters for electric hoists, European-style cranes, and small-tonnage gantry or bridge cranes, tailored to their load characteristics and control needs. They follow industry standards, come with integrated crane-specific functions, have a compact structure, and offer excellent performance. The entire series has built-in braking units, and through overall EMC design and rigorous reliability testing, they meet users’ environmental requirements for low noise and low electromagnetic interference, while greatly improving product reliability.

·0.7-37kW
·380V
·CE Certified
  • NVT GD20-09 Series Frequency Converter for Lifting
  • INVT GD20-09 Crane Frequency Converter
ImagesImages
  • NVT GD20-09 Series Frequency Converter for Lifting
  • INVT GD20-09 Crane Frequency Converter
Overview
Features
Specifications
Downloads
More Resources

产品特点

All models come standard with a built-in braking unit

01

Specialized terminal design, offering more choices

02

Dedicated brake logic

The brake logic controls the torque validation. Once the torque is established, it releases the brake, ensuring the vehicle doesn’t roll back. The brake logic control supports start direction and forward/reverse brake selection, meeting various startup requirements and offering good adaptability.

03

Application Macros

Integrates various lifting application macro modes and supports user-defined macros, making debugging one-click easy and applications simpler.

04

Conical rotor motor control

Adjusts the magnetic flux according to the characteristics of the conical rotor motor to achieve quick release and brake control, simplifies the setup steps, and ensures safety.

05

Specifications

Function Description

Specifications

Power Input

Input voltage(V)

AC 3PH 380V(-15%)~440V(+10%),rated voltage:380V

Input current(A)

Please refer to the 'Product Ratings'

Input frequency(Hz)

550Hz or 60Hz, allowed range 47~63Hz

Power output

Output voltage(V)

0~ Input Voltage

Output current(A)

Please refer to the 'Product Ratings'

Output power(kW)

Please refer to the 'Product Ratings'

Output Frequency(Hz)

0~150Hz

Technical control performance

Control method

Space voltage vector control (V/F), and sensorless vector control (SVC)

Motor type

Asynchronous motor

Speed ratio

Asynchronous motor 1:200(SVC)

Speed control accuracy

±0.2%(SVC)

Speed fluctuation

± 0.3%(SVC)

Torque Response

<20ms(SVC)

Torque control accuracy

10%(SVC)

Starting torque

Asynchronous motor:0.25Hz/150%(SVC)

Overload capacity

Meet the work schedule S3 load requirements

Braking ability

100% braking power for long-term operation, 120% braking power for 1 minute, 170% braking power for 10 seconds

Operation control performance

Frequency setting method

Digital setting, analog setting, multi-speed operation setting, MODBUS communication setting, etc.; realizes combination of settings and switching of setting channels

Automatic voltage regulation function

When the grid voltage changes, it can automatically maintain a constant output voltage

Fault protection function

Provides more than 30 fault protection functions: overcurrent, overvoltage, undervoltage, overtemperature, phase loss, underload, overload, etc.

Peripheral interface

Terminal analog input resolution

Not greater than 20mV

Terminal digital input resolution

Not greater than 2ms

Simulated Input

1 channel, AI2: 0~10V/0~20mA
Models of 5.5kW (inclusive) and above are compatible with PT100 resistance input; AI or PT100 is set via DIP switch;

Digital Input

8 channels of general-purpose input, two of which support PTC input; PTC actuates at 2.5kΩ;
Internal impedance: 6.6kΩ;
Maximum input frequency: 1kHz;
Supports internal 24V power supply;
Supports external power supply voltage input of (-20%) 24~48VDC (+10%), (-10%) 24~48VAC (+10%);
Bidirectional input terminals, supporting both NPN and PNP wiring methods.

Relay Output

Three programmable relay outputs
R01A normally open, R01B normally closed, R01C common terminal
R02A normally open, R02C common terminal
R03A normally open, R03C common terminal
Contact capacity: 3A/AC 250V, 1A/DC 30V

Others

Operating ambient temperature

-10~50℃; derating required for operation above 40℃

Protection degree

IP20

Pollution degree

Level 2

Cooling method

Forced air cooling

Braking unit

Built-in for the whole series

Altitude

Below 1000m; derating required for altitudes above 1000m, with 1% derating for every 100m increase

DC reactor

Models of 18.5kW (inclusive) and above are equipped with a built-in DC reactor as standard

EMC filter

Three-phase 380V 5.5kW (inclusive) and above products can meet the IEC61800-3 C3 class requirements, and jumper J10 can be connected by the user; other products can be equipped with an optional external filter to meet the IEC61800-3 C3 class requirements. The whole series of products can be equipped with an optional external filter to meet the IEC61800-3 C2 class requirements.

Downloads

Have questions or need support?

Our professional team is here to help.

Inquiry
TOP
We use cookies to understand how our audience uses our site.
Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie policy.
Accept
Reject
Cancel