| XD8KTR | XD10KTR | XD12KTR | XD15KTR |
Input DC (PV) | ||||
Max. usable PV input power | 12.8kW | 16kW | 19.2kW | 24kW |
Max. input voltage | 1000V | |||
Start-up voltage | 160V | |||
MPPT voltage range | 160V ~ 950V | |||
Max. input current per MPPT | 40A | |||
Max. short circuit current per MPPT | 50A | |||
MPPT number / Strings per MPPT | 2/ 2 | |||
Battery Input | ||||
Battery type | LiFePO₄ , Lead-acid battery | |||
Battery voltage range | 40V ~ 60V | |||
Max. charge / discharge power | 8kW | 10kW | 12kW | 15kW |
Max. charge / discharge current | 190A | 220A | 260A | 300A |
Number of battery port / BMS port | 2/21 | |||
Communication Interface | RS485/CAN | |||
Input / Output AC (Grid) | ||||
Rated output power | 8kW | 10kW | 12kW | 15kW |
Max. active output power | 8.8kW | 11kW | 13.2kW | 16.5kW |
Max. apparent output power | 8.8kVA | 11kVA | 13.2kVA | 16.5kVA |
Rated output current | 12.1A | 15.2A | 18.2A | 22.7A |
Max. output current | 13.3A | 16.7A | 20A | 25A |
Max. input current | 24.2A | 30.3A | 36.4A | 40A |
Rated grid voltage | 220V/380V,230V/400V | |||
Operating voltage range | 0.85Un~1.1Un | |||
Grid connection type | 3L/N/PE | |||
Rated grid frequency/ grid frequency range | 50Hz / 45~55Hz;60Hz/55~65Hz | |||
Power factor range | 0.8 leading ~0.8 lagging | |||
THDi | < 3% ( Rated Power, Resistive Load ) | |||
Output AC (Back-up) | ||||
Rated output power | 8kW | 10kW | 12kW | 15kW |
Max. apparent output power | 8.8kVA | 11kVA | 13.2kVA | 16.5kVA |
Rated output voltage, frequency | 220V/380V, 230V/400V, 50Hz/60Hz | |||
On/off grid switch time | < 10ms | |||
THDv | < 3% ( Rated Power, Resistive Load ) | |||
Peak output power, Duration | 16kW, 10s | 20kW, 10s | 24kW, 10s | 30kW, 10s |
Input AC (Generator) | ||||
Max. input power | 8kW | 10kW | 12kW | 15kW |
Rated input current | 12.1A | 15.2A | 18.2A | 22.7A |
Rated input voltage, frequency | 220V/380V, 230V/400V, 50Hz/60Hz | |||
Efficiency | ||||
Max. efficiency | 97.3% | |||
EU efficiency | 96.0% | |||
Max. battery charging efficiency by PV | 94.5% | |||
Max. battery discharge efficiency | 94.0% | |||
Protection | ||||
AC short-circuit protection | Yes | |||
AFCI | Optional | |||
Integrated DC switch | Yes | |||
Residual current protection | Yes | |||
Insulation resistance monitoring | Yes | |||
String current monitoring | Yes | |||
Surge protection | TYPE II ( DC ) / TYPE III ( AC ) | |||
General Data | ||||
Dimensions (W × H × D) | 513 x 727 x 274mm | |||
Weight | Approx. 47kg | |||
Topology | Non-isolated ( PV-Grid ), Isolated ( Battery ) | |||
Self-consumption | < 30W | |||
Operating temperature/ humidity | -30℃ ~60℃ /0%~100% ( Non-condensing ) | |||
Ingress protection rating | IP66 | |||
Noise emission (typical) | ≤ 50dB ( A ) | |||
Display | LCD | |||
Communication interface | Standard: RS485 / CAN / WLAN / Bluetooth Optional: 4G | |||
Cooling method | Smart cooling | |||
Max. operating altitude | 4000m | |||
PV DC connection | Plug-in MC4 Connector ( Jinko ) | |||
Battery DC connection2 | OT terminal direct-lock type (2 power cable sets, total 4 wires, ≥ 33-42mm²(2-1AWG), cable ≤ 1.5m) | |||
AC connection2 | Direct-lock type (Recommended cable ≥ 8-10mm²(8-7AWG)) | |||
Popular Searches:
XD8-15KTR
Three-Phase Hybrid Inverter
The XD8-15KTR is designed for residential energy storage, including homes in weak-grid areas. Dual MPPT trackers and a 40 A MPPT input support high-power PV modules and maximize rooftop solar yield. With 150% unbalanced output, 2× off-grid peak power, and 0 ms seamless switchover, it keeps critical loads and high-power appliances running through grid fluctuations and outages.
·Power Range: 8~15kW
·Battery Voltage Range: 40~60V
·Max. String Input Current: 20A
Features

High Energy Yield
01

Comprehensive Protection
02

Stable Backup Power
03

Flexible & Scalable
04
Specifications
More Resources
Have questions or need support?
Our professional team is here to help.



Inquiry
TOP
Popular Searches:
Repair Progress Tracking | Identity Verification
To protect your repair information, please verify using the mobile number reserved on the service order.
Verify with the reserved mobile number
Verify
SMS Verification Code *
If you cannot receive the code, please contact the after-sales hotline. 400-700-9997

Contact INVT
Get in touch with INVT. Our team will get back to you shortly.
Full Name *
Company Name *
Email Address *
Phone Number *
Country *
City
Inquiry Type *
Product Category *
Select the product you're interested in.
-
Industrial Automation
-
Network Power
-
PV & ESS
-
e-Mobility
Your Message / Requirements *
I have read and agree to INVT Privacy Policy and Terms of Use