| XD7KTL | XD8KTL | XD10KTL |
Input DC (PV) | |||
Max. usable PV input power | 11.2kW | 12.8kW | 16kW |
Max. input voltage | 600V | ||
Start-up voltage | 100V | ||
MPPT voltage range | 100V ~ 550V | ||
Max. input current per MPPT | 20A+40A | ||
Max. short circuit current per MPPT | 30A+60A | ||
MPPT number / Strings per MPPT | 2 / 1+2 | ||
Battery Input | |||
Battery type | LiFePO₄ , Lead-acid battery | ||
Battery voltage range | 40V ~ 60V | ||
Max. charge / discharge power | 7kW | 8kW | 10kW |
Max. charge / discharge current | 175A | 190A | 220A |
Number of battery port / BMS port | 1/1 | ||
Communication Interface | CAN | ||
Input / Output AC (Grid) | |||
Rated output power | 7kW | 8kW | 10kW |
Max. active output power | 7.7kW | 8.8kW | 11kW |
Max. apparent output power | 7.7kVA | 8.8kVA | 11kVA |
Rated output current | 31.8A/30.4A | 36.4A/34.8A | 45.5A/43.5A |
Max. output current | 35A/33.5A | 40A/38.2A | 50A/47.8A |
Max. input current | 50.9A/48.7A | 58.2A/55.7A | 72.7A/72.7A |
Rated grid voltage | 220V / 230V | ||
Operating voltage range | 187V ~ 253V | ||
Grid connection type | L/N/PE | ||
Rated grid frequency/ grid frequency range | 50Hz / 45~55Hz;60Hz /55~65Hz | ||
Power factor range | 0.8 leading ~0.8 lagging | ||
THDi | < 3%(Rated Power, Resistive Load) | ||
Output AC (Back-up) | |||
Rated output power | 7kW | 8kW | 10kW |
Max. apparent output power | 7.7kVA | 8.8kVA | 11kVA |
Rated output voltage, frequency | 220V / 230V,50Hz/60Hz | ||
On/off grid switch time | <10ms | ||
THDv | < 3% ( Rated Power, Resistive Load ) | ||
Peak output power, Duration | 14kW,10s | 16kW, 10s | 20kW, 10s |
Input AC (Generator) | |||
Max. input power | 7kW | 8kW | 10kW |
Rated input current | 31.8A/30.4A | 36.4A/34.8A | 45.5A/43.5A |
Rated input voltage, frequency | 220V / 230V,50Hz / 60Hz | ||
Efficiency | |||
Max. efficiency | 98.0% | ||
EU efficiency | 97.5% | ||
Max. battery charging efficiency by PV | 97.0% | ||
Max. battery discharge efficiency | 95.0% | ||
Protection | |||
AC short-circuit protection | Yes | ||
AFCI protection | Optional | ||
Integrated DC switch | Yes | ||
Residual current protection | Yes | ||
Insulation resistance monitoring | Yes | ||
String current monitoring | Yes | ||
Surge protection | TYPE Ⅱ(DC)/TYPE Ⅱ(AC) | ||
General Data | |||
Dimensions (W × H × D) | 440 x 534 x 245 mm | ||
Weight | Approx. 32kg | ||
Topology | Isolated (Battery) | ||
Self-consumption | < 10W | ||
Operating temperature/ humidity | -30℃ ~60℃ /0%~100% (Non-condensing) | ||
Ingress protection rating | IP66 | ||
Noise emission (typical) | ≤ 40dB (A) | ||
Display | LCD | ||
Communication interface | Standard: RS485 / CAN / WLAN /Bluetooth; Optional: 4G | ||
Cooling method | Smart Forced-Air Cooling | ||
Max. operating altitude | 4000m | ||
PV DC connection | PV-JK00M1 | ||
Battery DC connection | OT Terminal (35~50mm²) | ||
AC connection | Straight-Locking Type | ||
Grid standard1 | IEC61727 | ||
Safety / EMC standards1 | IEC/EN 62109-1/2, IEC/EN 61000-1/3, EN50549, IEC 61727/62116 | ||
XD7-10KTL
Single-Phase Hybrid Inverter
The XD7-10KTL is designed for residential solar and energy storage applications. Dual MPPT trackers, 150% DC oversizing, and up to 98% efficiency maximize rooftop solar yield and reduce electricity costs. IP66 protection, AC/DC Type II surge protection, AFCI, and a −30°C to +60°C operating range ensure reliable outdoor performance. Supporting on-grid and off-grid operation, parallel expansion, and lithium-ion and lead-acid batteries, it is ideal for self-consumption, backup power, and scalable home energy systems.
Features




Specifications
Downloads
More Resources
Have questions or need support?
Our professional team is here to help.



Repair Progress Tracking | Identity Verification
To protect your repair information, please verify using the mobile number reserved on the service order.

Contact INVT
Get in touch with INVT. Our team will get back to you shortly.
-
Industrial Automation
-
Network Power
-
PV & ESS
-
e-Mobility