GD20 Series Compact VFD

The GD20 series Variable Frequency Drive (VFD) adopts sensorless vector control technology, delivering excellent drive performance and offering powerful control functions. With comprehensive hardware configuration and advanced software features, it offers significant improvements in usability and reliability to better meet the diverse requirements of various industrial applications. The 18.5–110kW models come standard with a built-in DC reactor. The 18.5–37kW models feature a standard built-in braking unit, while the 45kW–110kW models offer an optional built-in braking unit. The entire series features an independent air duct design, which improves reliability and performance, enhancing overall product competitiveness.

·0.4-110kW
·CE and EAC certified
  • GD20 Series Compact VFD
  • GD20 Series Compact VFD
  • GD20 Series Compact VFD
ImagesImages
  • GD20 Series Compact VFD
  • GD20 Series Compact VFD
  • GD20 Series Compact VFD
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Excellent control performance
Adopts sensorless vector control for superior performance. Features static and rotary motor parameter autotuning.
01
Optimized structural design
Compact dimensions save valuable installation space.
02
Rich configuration and interfaces, powerful functionality
Standard built-in RS485 communication interface, multiple I/O terminals, and an external keypad interface for flexible field applications.
Built-in DC reactor (standard for models 18.5–110kW)to improve power factor.
Built-in braking unit (standard for models ≤37kW; optional for models 45–110kW).
03
Multiple mounting methods
380V models (≤2.2kW) support both DIN rail mounting and wall mounting; 380V models (≥ 4 kW) support wall and flange mounting.
04
Ease of use and maintenance
Supports independent installation and removal of the cooling fan for easy maintenance.
Standard configuration includes an external LED keypad; supports an optional LED keypad with parameter copy function available for diverse application needs.
05
Integrated functions for versatile applications
Includes simple PLC, multi-speed control, built-in PID, torque control, multi-point V/F curves, multiple braking methods, transient power loss ride-through, and more.
06

Specifications

Item Specifications 
Power input Rated input voltage (V) 1PH 220V (-15%)–240V (+10%) 3PH 220V (-15%)–240V (+10%) 3PH 380V (-15%)–440V (+10%)
Rated input current (A) For details, see the product ratings in the manual.
Rated frequency (Hz) 50Hz or 60Hz; allowed range: 47–63Hz
Power output Rated motor capacity (kW) For details, see the product ratings in the manual.
Rated output (kVA) For details, see the product ratings in the manual.
Rated current (A) For details, see the product ratings in the manual.
Rated output voltage (V) Equal to the input voltage, with the error <5%.
Technical control performance Control mode Space voltage vector control, and sensorless vector control (SVC)
Motor type Asynchronous motor (AM)
Speed regulation range 1:100
Speed control accuracy ±0.2% (SVC)
Speed fluctuation ± 0.3% (SVC)
Torque response <20ms (SVC)
Torque control accuracy 10%
Starting torque 0.5Hz 150% (SVC)
Overload capacity 150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 1 second
Control characteristics Frequency setting method Settings can be implemented through digital, analog, pulse frequency, multi-step speed running, simple PLC, PID, Modbus communication, and so on. Settings can be combined and the setting channels can be switched. Settings can be combined and the setting channels can be switched.
Automatic voltage regulation (AVR) The output voltage can be kept constant although the grid voltage changes.
Fault protection Various protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload.
Speed tracking restart function Enables smooth startup of a rotating motor.
Analog input One input (AI2) 0–10V/0–20mA; one input (AI3) -10–+10V
Analog output Two inputs (AO1, AO2) 0–10V/0–20mA
Digital input Four regular inputs; max. frequency: 1kHz One high-speed input; max. frequency: 50kHz
Digital output One Y1 terminal output
Relay output Two programmable relay outputs RO1A: NO; RO1B: NC; RO1C: common RO2A: NO; RO2B: NC; RO2C: common Contact capacity: 3A/AC250V, 1A/DC30V
Other DC reactor Models ≥18.5kW: Standard built-in
Mounting method 1PH 220V/3PH 380V (≤2.2kW) & 3PH 220V (≤0.75kW): DIN rail and wall mounting 3PH 380V (≥4kW) & 3PH 220V (≥1.5kW): Wall and flange mounting
Braking unit Models ≤ 37kW: Standard built-in Models 45–110kW: Optional built-in
EMC filter 3PH 380V (≥4kW) & 3PH 220V (≥1.5kW): Optional built-in C3 filter All models: Optional external C2 filter Optional filters: IEC 61800-3 C2, IEC 61800-3 C3
Temperature of running environment -10°C–+50°C. Derating is required when the ambient temperature exceeds 40°C.
Altitude Below 1000m (Derating is required when the altitude exceeds 1000m. Derate by 1% for every increase of 100m.)
Ingress protection (IP) rating IP20 Note: VFDs with plastic housings must be installed in a metal distribution box that meets IP20 and provides IP3X protection at the top.
Compliance CE
Cooling method Forced air cooling

Downloads

Have questions or need support?

Our professional team is here to help.

Inquiry
TOP
We use cookies to understand how our audience uses our site.
Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie policy.
Accept
Reject
Cancel