Q
What is the input power factor of GD5000?
2021-02-02
A

GD5000 input power factor ≥0.97.

Q
What is the maximum power output by GD3000?
2021-02-02
A

The maximum power of GD3000/1140V product is 1000kW, and the maximum power of GD3000/3300V product is 2500kW

Q
Can solar pumping controller GD100-PV supply for other house applications?
2021-02-02
A

No, GD100-PV can only drive pump, its output is not sine waveform. If need supply to house application need to choose solar inverter.

Q
How to deal with A-LL failt for BPD?
2021-02-02
A

A-LL fault is a water tank empty,underload fault. If a water level switch is used, please check whether the water level switch is normally open and normally closed. If the water level switch is not used, it means that the motor has no-load operation or the motor running current is too low to trigger undervoltage protection. You can reduce the percentage of underload deteck point P15.17.

Q
How to connect external braking resitance and what are the related parameters?
2021-02-02
A

Connect resistance between '+' and 'B2'. It needs to remove the connector between B2 and B3 in small power drives; The related parameters are P0.13 power of external braking resistance; P0.14 resistance value of external braking resistance; P4.34=2  external braking resistance enabled.

Q
It shows ER05-0 error after customers modify motor code in the keypad, what's the reason?
2021-01-27
A

There are two parts of the motor codes: high bit and low bit. Probably customers only change the low bit of the motor code, but didn't change the high bit, so the motor codeis wrong, and it shows ER05-0 error.

Q
What's the difference between VS HMI and VK/VT HMI?
2021-01-27
A

The programming software of VS HMI is HMITool and VK/VT HMI is programmed by VT Designer, and VS HMI is economic model whose price is good.

Q
What are the main features of AX series PLC and what's the main difference between AX70 and AX71 PLC?
2021-01-27
A

Features:
1. Support EtherCAT distributed IO, and maximum up to 32,000 points;
2. Excellent motion control function including interpolation, chasing cut, flying cut and so on;
3. Visualization configuration, support IL, LAD, FBD, SFC, ST, CFC 6 programming language;
4. Abundant field bus including EtherCAT, CANopen, Ethernet and modbus;

The main difference between AX70 and AX71:
AX70 can support 32 axes via EtherCAT communication, and AX71 can only support 8 axes.

Q
What's the output type of IVC series PLC?
2021-01-27
A

'R': relay output; 'T': transistor output(NPN); Please note that INVT PLC doesn't support PNP output.

3233343536 Show:
You can also view:
Service IntroductionValue added ServiceTraining DownloadFAQsProduct Query

Product Inquiry
Name:*
Company:
Country:*
E-mail Address:*
Phone:
Content:*

Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie Policy.