Q : How to fix STo fault with abnormal noise and vibration on GD350-185G-4 driving a synchronous motor?

Views : 2
2025-10-24

A: GD350-185G-4, 

Application condition: Speed regulation of synchronous motor powder selection machine. 

Fault phenomenon: There is abnormal noise and mechanical vibration from the motor during startup, which is reported as STo.

 How to solve it?

Cause analysis: 

Check that the motor parameter settings are correct. 

Check the synchronous motor magnetic pole detection P13.01=2, P13.06=80%. 

Observe that the current is unstable during operation.

Solution: 

Optimize P13.06 to eliminate motor abnormal noise at the moment of starting after 30%. 

Optimize the speed loop control parameters of P3 group. 

Improvement effect: 

smooth start stop and stable operation.

Have questions or need support?

Our professional team is here to help.

Inquiry
TOP
We use cookies to understand how our audience uses our site.
Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie policy.
Accept
Reject
Cancel