Q : How to connect the single phase pump with GD100-PV?
A: 1.General connection:Pump LN connect to inverter UW.
2.Three wires connection:Remove capacitor,then connect with UVW cable,ensure resistance of UW is minimum,resistance of UV is maximum.Short connect S4&COM terminal.