ETH failure means that the drive board has a short-circuit to ground or the current detection circuit is partially damaged.
-1. First, the inverter restores the factory settings, P00.18=1. Reset the motor parameters P02.01-P02.05.To see whether it will work.
-2. Try to replace the control board 34PIN horn cable or control board.
If the problem is still not resolved, the driver board needs to be replaced.
You can set P15.06,P15.07,P15.08,P15.09 to be larger, such as 15, 20, 25.
Yes,use internal PID funtion to realize this. Need customized special non-standard firmware.
1.Different protection level. BPD is IP65,GD100-PV is IP20.
2.Different power range.GD100-PV has full power range,BPD only have below 5.5kw.
3.Different configuration.BPD built-in BOOST module and auto switch module,GD100-PV is external module.
Support the master-slave control mode. Each inverter needs to be equipped with a CAN master-slave card,and it support the master-slave speed mode and torque mode.
Standard LCD keyboard, currently supports Chinese, English, and Russian display, supports parameter upload/download function, and can customize monitoring and debugging parameters.
At the same time, it supports optional LED keyboard.
Standard Modbus RTU (RS485), optional expansion card supports ProfiBus DP, ProfiNet, CANopen, Ethernet/IP, Modbus TCP, etc.
Support V/F, open loop vector and closed loop vector modes. Closed-loop vector speed mode, you can use the HDIA and HDIB two high-speed pulse inputs on the control board to receive encoder signals, or you can extend the PG card to use.
The standard supports asynchronous motors and synchronous motors. The motor type and parameters can be set in the P02 group motor parameters.