INVT iSmart Micro Data Center Powers Local Edge Computing in the Middle East

Release time:2025-11-13
Click amount: 113

Abstract: With the acceleration of digital transformation (the global edge computing market size grew by 27% year-on-year as of Q3 2025), and the development of data centers in some regions is constrained by high construction costs, difficulties in obtaining land approval, and long construction periods. Given the above, INVT iSmart series micro data centers, due to its high degree of integration and scene adaptability, has become a key technical carrier for edge computing, rapid deployment, and energy efficiency optimization.

Keywords: Micro data center, office server, precision air conditioner.

The iSmart series single cabinet data center integrates UPS, air conditioner, power distribution module, power and environment monitoring system, temperature and humidity detection, light and access control in a standard 19-inch server cabinet. All equipment is pre-installed and precommissioned in the factory. The on-site installation is easy and convenient, which can realize rapid deployment, occupy less area, and come with remote web interface monitoring function, which can realize remote operation and maintenance of a site. 

Project introduction

INVT's partners in the Middle East have a requirement to set up an actual server room in their offices for local real-time data processing, providing local data exchange and storage services; at the same time, it should enable other partners or potential clients to view the products in real time and receive training. The client adopted the INVT iSmart Series Single Cabinet Data Center solution, which includes functions such as UPS, backup power redundancy, integrated precision air conditioning, and environmental monitoring.

System configuration

The information of the iSmart series of miniaturized integrated data centers from Yingzhi is as follows: IS160

20251113-01-1.png

  Precision air conditioner's information is as below: VCS003UH

20251113-04-01.png

    Inverter integrated rack air conditioner

 The UPS and battery are as follows:

20251113-05.png

Power & Environment Monitoring System as follows:
20251113-11-01.png

Difficulty, solution and advantages
1.    Difficulty: Without enough building space, how can the client build a data center
• The overall area of a single cabinet is 0.72㎡, which is suitable for computer rooms within 10-20 ㎡, such as small archives.
• Computer rooms suitable for small and medium-sized enterprises, large enterprises and government branches; financial business offices, communication business offices, halls and base stations; commercial retail institutions, tourist attractions; gas stations, toll stations, intelligent buildings; grassroots public security institutions, government agencies.

2.    Difficulty: Can the subsequent machines be further expanded and upgraded?
• The monitoring system is extensible and compatible with thirdparty monitoring systems;friendly HMI.
• Support local and remote WEB interface access, SMS alarm function.

3.    Difficulty:How to solve the problems of installation and maintenance?
• Modular design of power distribution, easy installation and maintenance.
• Rack-mounted air conditioner indoor unit, pipe thread connection, easy maintenance.
• The computer room does not need special decoration treatment, and the equipment is ready to use. Installation and commissioning cycle only need 3 hours.
• A single cabinet is a complete system, plug and play.