Yes, but solar power is unstable, may not keep runs 50Hz all the time, so if your speed requirment is lower is acceptable.
1.Insure solar input total Vmp>=550VDC.
2.When weak light or cloudy is normal.
3.If configuration is no issue,and frequence keep under 50Hz,please contact INVT company.
Recommanded use float switch sensor,don't support analog sensor.
Only need to set P15.05 lower frequence of PI output,no need to set P00.05.
1.General connection:Pump LN connect to inverter UW.
2.Three wires connection:Remove capacitor,then connect with UVW cable,ensure resistance of UW is minimum,resistance of UV is maximum.Short connect S4&COM terminal.
GD100-PV is a professional photovoltaic water pump driver. The -SS2 model integrated a special single-phase pump special algorithm, which can support driving single-phase 220V pumps. Divided into two kinds of schemes, one is not to dismantle the water pump capacitor, directly connected to U and W terminals. Another solution needs to removed the water pump capacitors,connected to the UVW terminal according to the schematic diagram in the GD100-PV operating manual.Normally we suggest to remove the water pump capacitors.
MPPT is the abbreviation of Maximum power point tracking,according to the working principle of photovoltaic panels, the VFD must support the MPPT function to ensure that the photovoltaic panels always work at the maximum power output point, otherwise the photovoltaic panels cannot work at the best status.
Voc is the open circuit voltage of the photovoltaic panel, and Vmp is the maximum power point voltage. When calculating, use Vmp to calculate the number of photovoltaic panels. After calculation, you need to consider that the total Voc voltage is less than the overvoltage point of GD100-PV.In the manual, there are the suitable solar panel conficuration.