GD270 Series VFD for Fan and Pump

GD270 is a new member of INVT’s Goodrive series. It comes with built-in functions tailored for fan and pump applications, and adopts advanced vector control algorithms and energy-saving technologies. It can effortlessly drive loads such as fans and pumps, making it ideal for wastewater treatment, municipal water supply/heating, HVAC, and other industries.

·0.75-500kW
·Equipped with the ECO energy-saving control algorithm
  • GD270 Series VFD for Fan and Pump
  • GD270 Series VFD for Fan and Pump
VideoVideo
ImagesImages
  • GD270 Series VFD for Fan and Pump
    GD270 Series VFD for Fan and Pump
  • GD270 Series VFD for Fan and Pump
  • GD270 Series VFD for Fan and Pump
Overview
Features
Specifications
Downloads
More Resources
Case
Videos
More

Features

Features
Equipped with a newly developed ECO energy-saving control algorithm to ensure optimal performance and minimum loss at low dynamic loads, optimizing output power.
Supports permanent magnet synchronous motors (PMSM), enhancing system efficiency and reducing operating costs.
01
Easy to use
Built-in dedicated functions for fans, pumps, and HVAC, ready for immediate use, significantly improving commissioning efficiency.
Supports deragging (pump cleaning) and multi-pump control, reducing daily maintenance workload, simplifying the control system, and lowering overall costs.
02
Stable and reliable
Wide voltage design of 380–480V, effectively handling grid fluctuations and improving grid adaptability.
Meets 3C3 and 3S3 requirements, significantly enhancing reliability in harsh environments.
03
Flexible configuration
Optional built-in DC reactor and output AC reactor, meeting harmonic requirements for different scenarios.
Supports mainstream industrial bus expansion options (Profibus-DP, Profinet, CANopen, Ethernet/IP, Modbus-TCP), allowing on-demand configuration.
04

Specifications

ItemSpecifications
Power input Input voltage (V) AC 3PH 380–480V; rated voltage: 380V
Allowed voltage transient fluctuation -15%~+10%
Input current (A) Refer to the GD270 ratings table in the manual.
Input frequency (Hz) 50Hz or 60Hz; allowed range: 47–63Hz
Power output Output voltage (V) 0–input voltage
Output current (A) Refer to the GD270 ratings table in the manual.
Output power (kW) Refer to the GD270 ratings table in the manual.
Output frequency (Hz) 0–400Hz
Technical control performance Control mode Space voltage vector control, and sensorless vector control (SVC).
Motor type Asynchronous motor (AM) and permanent magnet synchronous motor (SM)
Speed ratio Asynchronous motor (AM): 1:200 (SVC) Synchronous motor (SM): 1:20 (SVC)
Speed control accuracy ±0.2% (SVC)
Speed fluctuation ±0.3% (SVC)
Torque response <20ms (SVC)
Torque control accuracy ±10% (SVC)
Overload capacity Able to run at 110% of rated current for 1min. Overload is allowed once every 5min.
Running control performance Frequency setting method Settings can be implemented through digital, analog, pulse frequency, multi-step speed run, simple PLC, PID, and communication. Settings can be combined and the setting channels can be switched.
Automatic voltage regulation (AVR) The output voltage can be kept constant although the grid voltage changes.
Fault protection Various protection functions, such as protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload.
Start after speed tracking Enables smooth startup of a rotating motor.
Peripheral interface Terminal analog input resolution No more than 20mV
Terminal digital input resolution No more than 2ms
Analog input Two inputs. AI1: 0(2)–10V / 0(4)–20mA AI2: -10–+10V
Analog output Two outputs. AO0/AO1: 0(2)–10V/0(4)–20mA
Digital input Four regular inputs; max. frequency: 1kHz; internal impedance: 3.3kΩ One high-speed input; max. frequency: 50kHz
Digital output One Y terminal open collector output, sharing the terminal with S4. The function can be selected through a jumper.
Relay output One programmable relay output RO1A: NO; RO1B: NC; RO1C: common Contact capacity: 3A/AC250V, 1A/DC30V
Expansion interfaces Two expansion interfaces: SLOT1, SLOT2 Support communication cards, I/O cards, and other expansion cards.
Other Mounting method Supports wall mounting, floor mounting, and flange mounting.
Temperature of running environment -10°C–+50°C. Derating is required when the ambient temperature exceeds 40°C.
Ingress protection (IP) rating Models ≤ 200kW: IP20 Models ≥ 220kW: IP00
Pollution degree Degree 2
Cooling method 1.5kW: Natural air cooling ≥ 2.2kW: Forced air cooling