Item | Specifications | |
Input and output | Input voltage | AC400V±15% |
| Input frequency | 47~63Hz | |
| Output voltage (V) | 0–Input voltage (V) | |
| Output frequency (Hz) | 0–400Hz | |
Elevator basic features | Maximum floors | 64 floors |
| Maximum running speed | 6m/s | |
| Group-control ability | Maximum 8 elevators | |
| Communication mode | 2 sets of CANbus communication ports, 2 sets of Modbus communication ports | |
Technical Performance | Control mode | PG vector control |
| Overload capability | 60s for 150% overcurrent; 10s for 180% overcurrent | |
| Starting torque response | PG vector control:0Hz/150% | |
| Speed control accuracy | PG vector control:±0.1% max speed | |
| Carrier frequency | 1.0kHz~16.0kHz | |
Peripheral interface | Low-voltage digital input terminals | 26 low-voltage digital input channels, DC24V / 4.5–8mA. The input mode (active low or active high) can be selected via the PW DIP switch. |
| High-voltage detection input terminals | 5 high-voltage detection input channels, AC/DC 110V | |
| Digital output terminals | 6 digital output channels, DC30V / 5A, AC250V / 5A. Among them, Y3–Y6 support multifunction output settings via parameters F0_70 / F0_71 | |
| CAN communication ports | 2 independent CAN communication ports | |
| Encoder interfaces | Built-in encoder interfaces supporting sine-cosine, open-collector NPN output, and push-pull output. Expandable support for EnDat encoders, UVW encoders, and resolver interfaces | |
Features | Operation mode | Normal run, inspection, re-leveling, door-open re-leveling, UPS operation, and hoistway self-learning |
| Stopping method | Distance-based stopping principle, with real-time generation of the travel curve for direct and precise leveling. | |
| Starting torque compensation | Two independent regulation methods using the speed loop and position loop, enabling smooth start without a load weighing device. | |
| Motor auto-tuning | Synchronous motors use load-based rotational auto-tuning, while asynchronous motors use static auto-tuning | |
| Hoistway auto-tuning | Accurately records floor positions and forced deceleration switch positions | |
| Automatic voltage regulation | Maintains constant output voltage automatically when grid voltage fluctuates | |
| Energy feedback | In the power generation state, the drive feeds electrical energy back to the grid. | |
Operating and monitoring | Operator keypad | Composed of a 5-digit LED display, 8 indicator LEDs, and 5 keys. It supports fault inquiry, call commands, motor auto-tuning, hoistway self-learning, and test operations. For details, refer to Section 8.5. |
| Handheld operator | Supports parameter setting, parameter upload and download, soft fault inquiry, and manual call operations | |
| APP Easy-Commissioning software | Supports parameter setting, parameter upload and download, fault inquiry, and manual call operations | |
EC300B Integrated Elevator Controller
EC300 four quadrant intelligent integrated machine is a new generation of four quadrant intelligent elevator control system integrating the drive technology, energy feedback technology, control technology, network communication technology as a whole design concept. It’s organically integrated as a whole through the four quadrants drive, control, management, and applied to the unique potential load occasions of the elevator field, there is a full range improvement and optimization of the product in the energy efficiency, safety and reliability, ease of operation, economic and practical aspects.
Features




Specifications
More Resources
Have questions or need support?
Our professional team is here to help.



Repair Progress Tracking | Identity Verification
To protect your repair information, please verify using the mobile number reserved on the service order.

Contact INVT
Get in touch with INVT. Our team will get back to you shortly.
-
Industrial Automation
-
Network Power
-
PV & ESS
-
e-Mobility