Q
Can 220VAC servo DA200 drive support single phase 220VAC input?
2021-03-04
A

Models(<=1kW) can support both single phase and three phase 220VAC input; Model(>=)1.5kW) has to connect with three phase 220VAC input, if with single phase 220VAC input, it will affect the maximum speed of motor, and has to use derately, which means a 1.5kW drive may be just uesd as 750W model.

Q
Will the protection level be affected after the BPD opens the cover?
2021-03-04
A

After the BPD is removed the cover to repaired, the protection level will decrease. When installing it again, you need to check whether the waterproof tape is intact, and apply appropriate waterproof glue on the four corners to ensure good sealing.

Q
Some foreign language can be showed in off line simulation mode, but cannot show in the screen after download(VS HMI)
2021-03-04
A

Please try‘Arial' font first. If it doesn't work, try to copy the language to 'word' document to know the exact font, for example, it should be 'Shruti' font for Indian language. Note: The 'systemFont' file in the installation directory of VS HMITool should have this font format.

Q
Does the IO cables sell together with AX PLC CPU?
2021-02-25
A

No. The CPU is sold without any spare parts including cables; it needs to buy the IO cable and terminal seperately.

Q
What's the meanings of suffix -1, -2 and -6 of IVC1L modules(IVC1L-1614MAR1/IVC1L-1614MAR2/IVC1L-1614MAR6)?
2021-02-25
A

-1: with integrated 2 analog inputs and 1 analog output;
-2: with removable ternimal;
-6: with integrated 2 analog inputs and 1 analog output and removable terminal;

Q
When VFD startup, after a few secdons, dEU failure is reported. How to solve it?
2021-02-25
A

dEU is the speed deviation fault. Set the speed and detect the speed deviation. After the detection time is exceeded, the inverter will stop reporting the dEU fault. The reason may be that the load is too heavy or the rotor is blocked, which causes the speed deviation to be too large. It is necessary to check the load condition, extend the speed deviation detection time, and adjust the speed loop PI parameters according to the control mode to increase the reduced output torque.

Q
What special air compressor functions does GD300-0A have?
2021-02-25
A

Sleep and wake-up function, constant voltage control, constant temperature control, component maintenance, hardware lack phase detection, phase sequence detection, fan overload protection, fan current imbalance protection, etc.

Q
Fpr GD300-21, what is the size of the HMI? What sizes are available?
2021-02-25
A

Usually we provide 7-inch HMI, with 10-inch and 4.3-inch options.

Q
Is it possible to use a third-party HMI to connect GD300-21?
2021-02-20
A

Third-party HMI can be connected to GD300-21 through Modbus RTU communication. The communication protocol in the manual is open to customers, but the HMI program needs to be configured by the customer.

23456 Show:
Vous pouvez également voir:
Présentation du serviceService à valeur ajoutéeFormation TéléchargerQFPsRequête de produit
Demande de produit
Nom:*
Société:
Pays:*
Adresse e-mail:*
Téléphone:
Teneur:*

Notre site utilise des cookies pour vous offrir une meilleure expérience sur site. En poursuivant votre navigation, vous acceptez notre utilisation des cookies conformément à nos Politique relative aux cookies.